11 Fault Finding
11.1 Indicated Faults
SOLO2 Transmitter and SOLO4 Transmitter
LED Condition
Meaning
Action
ALARM LED lit
permanently
Unit alarm, likely to be
no video input lock
Ensure video source connected
and of correct video standard
(PAL/NTSC)
SOLO2 Receiver and SOLO4 Receiver
LED Condition
Meaning
Action
ALARM LED lit
RF LED off
No RF Signal Lock
Check a suitable RF source is active,
on correct frequency.
Ensure Downconverters are
connected.
Ensure antennas are connected to
downconverters.
Ensure there is no interfering signal.
ALARM LED lit
RF LED on
Has RF signal lock but no
decoder lock
Check video is enabled at the
transmitter.
Check correct unit name is selected
at the receiver to match the
transmitter.
ALARM LED lit
Lock LED lit
RF LED on
Has RF signal lock but no
decoder lock due to
encryption of video
Check that scrambling keys are
matched.
Check video is enabled at the
transmitter.