Chapter 6: Maintenance and troubleshooting
98-141368-A 99
00270 to
00279
Voice module
error
Voice services cannot be
accessed by the terminal
Contact your distributor.
00280 to
00289
Ethernet module
error
The Ethernet interface on the
terminal cannot be used.
Contact your distributor.
00300 to
00309
GPS module error The GPS module is out of
function. The terminal cannot
obtain a valid GPS position.
Contact your distributor.
00340 to
00349
2-wire failure The Phone interface of the
terminal cannot be used.
Contact your distributor.
00350 to
00359
AD9864
calibration data
error
Internal error in the receiving
part of the terminal.
Contact your distributor if the
problem persists.
00360 to
00369
No antenna found The terminal cannot
communicate with the
antenna.
Check the cable between
terminal and antenna.
Reboot the terminal.
01010 to
01019
Temperature too
low (critical)
Low ambient temperature is
causing the performance of
the terminal to be degraded or
halted.
Move the terminal to a warmer
location.
For information on ambient
temperature limits, see the
installation manual.
01020 to
01029
Too low
temperature
warning
Low ambient temperature is
causing the performance of
the terminal to be degraded or
halted.
The terminal will assume radio
silence if the problem is in the
ACM module of the antenna.
Move the terminal to a warmer
location.
For information on ambient
temperature limits, see the
installation manual.
01110 to
01119
Temperature too
high (critical)
Terminal: Critically high
temperature is causing the
terminal to shut down.
Antenna: Critically high
temperature is causing the
antenna to stop transmission.
If possible, move the failing
unit to a cooler location.
For information on ambient
temperature limits, see the
installation manual.
Contact your distributor if the
problem persists.
01120 to
01129
Too high
temperature
warning
High ambient temperature is
causing the performance of
the system to be degraded or
halted.
The bit rate is reduced.
Move the terminal to a cooler
location.
For information on ambient
temperature limits, see the
installation manual.