COBHAM C406-2 SERIES Spezifikationen Seite 20

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 30
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 19
Artex Aircraft Supplies, Inc. 570-0049 Revision -
Page 20 of 30
7.4 453-0032 WIRING
Table 9: Remote Switch Interface 453-0032 Front View
VIEW PIN # SIGNAL DESCRIPTION
1 N/A
2 N/A
3 Reset 2
4 Aircraft Power (14 or 28 VDC)
5 Light (28 VDC Installation)
6 Reset 1
7 External ON
8 Light (14 VDC Installation)
9 Aircraft Ground
7.4.1 The wires for the interface 453-0032 are crimped and inserted inside the D-sub connector 150-
0022 using the same procedure highlighted in the “Cable Harness” section.
NOTE: Do not close the backshell if the two communication wires have not been installed yet.
Refer to section “453-0032 wiring to 453-0041” in this document to complete the entire
wiring process.
7.4.2 Install the D-sub connector inside a backshell (151-0006) at the completion of the crimping
process.
7.4.3 Secure the strain relief using the screws provided in the backshell kit.
7.4.4 Install the thumbscrews and close the backshell with the screws.
7.4.5 Attach the backshell to the 453-0032 interface using a torque between 1.5 and 2.0 in-lb (.7 to .22
Nm) at the completion of the entire wiring process.
NOTE: Accidently attaching the interface 453-0041 to the backshell instead of the 453-0032 does
not harm the ELT, the toggle switch 140-3349, or any of the interfaces. The outcome is
that the ELT cannot be activated remotely through the toggle switch 140-3349.